According to the label From the product label
These details were extracted from this product's label PDF.
The label is the law.
Confirm every rate, site, restriction and safety requirement against the label before mixing or applying.
Check for a
state supplemental label; a product may be restricted or prohibited in a state or site even when a rate appears below.
·
EPA registration data for Reg. 7969-400 →
This product is a Termidor H•P II finished dilution used to treat various sites. It is applied to horizontal treated zones on the soil surface, through foundation walls or floors, in sump pump pits, via the backfill method in trenches, and along the exterior or interior of plenum construction. Application methods include using a nozzle at 25 PSI or less with a coarse nozzle, drilling through foundations, or using short-rodding or long-rodding techniques.
Pests covered (2)
TERMITESDRYWOOD TERMITES
Areas treatable (25)
horizontal treated zones (soil surface)horizontal treated zones (through foundation wall or floor)sump pump pitBackfill Method (trench)Plenum Construction (exterior)Plenum Construction (interior)WOOD POLES/POSTSCONCRETE SLABSWOOD STRUCTURESWOOD SIGNSUTILITY AREASCOMMERCIAL/INSTITUTIONAL/INDUSTRIAL BUILDINGS (WALL VOIDS)ORNAMENTAL TREES (INJECTION TREATMENT)BASEMENTSGARAGESPLUMBING INSTALLATIONSBUILDING FOUNDATIONSWALLSEXPANSION JOINTS (CONCRETE)WOOD LANDSCAPING MATERIAL (SOIL CONTACT NONFUMIGATION TREATMENT)WOOD POLES/POSTS (SOIL CONTACT NONFUMIGATION TREATMENT)RESIDENTIAL AREAS (INJECTION TREATMENT)BUILDINGS (EXTERIOR)WOOD SIGNS (SOIL CONTACT NONFUMIGATION TREATMENT)DRAINS
How to treat each type of area 6
horizontal treated zones (soil surface)
| Location |
Rate |
Unit |
Dilution |
Label notes |
| Outdoor |
1.0 to 1.5 |
gallons |
Termidor H•P II finished dilution |
per 10 square feet using a nozzle pressure of 25 PSI or less and a coarse application nozzle (e.g., Delavan Type RD Raindrop®, RD-7 or larger, or Spraying Systems Co. 80110LP Teejet® or comparable nozzle). DO NOT broadcast or power spray with high pressure. |
horizontal treated zones (through foundation wall or floor)
| Location |
Rate |
Unit |
Dilution |
Label notes |
| Outdoor |
1.0 to 1.5 |
gallons |
Termidor H•P II finished dilution |
drill (no wider than 18 inches apart) through the foundation wall or through the floor above and treat soil adjacent to the foundation wall per 10 square feet. Soil adjacent to foundation elements may be treated with short-rodding or long-rodding techniques without drilling if access for treatment tool to soil site is available. |
sump pump pit
If water is in the sump pump pit, unplug the sump pump and remove four cups of water from the sump pump pit. Mark the water level. Wait 10 minutes and check the water level in the sump pump pit again. If the water level has risen, there is too much seepage to perform the treatment at this time. If the water level does not rise, make the treatment provided the sump pump remains unplugged. During application, check the sump pump pit every few minutes for the presence of Termidor ® H•P II High Precision Termiticide finished dilution. If detected, stop treatment immediately and remove the contents of the sump pump pit before plugging in the sump pump again.
- Location
- Outdoor
- Dilution
- Termidor H•P II finished dilution
Backfill Method (trench)
| Location |
Rate |
Unit |
Dilution |
Label notes |
| Outdoor |
2 |
gallons |
Termidor H•P II finished dilution |
per 10 linear feet per foot of depth of the trench, or 1.0 gallon per cubic foot of soil. Mix Termidor H•P II finished dilution thoroughly into the soil to contain the liquid and prevent runoff or spillage. |
Plenum Construction (exterior)
apply Termidor H•P II according to the Creating Vertical Treated Zones section of the label along the exterior of the foundation walls.
- Location
- Both
- Dilution
- Termidor H•P II
Plenum Construction (interior)
Ensure the sealing fabric and anything on the sealing fabric is removed to expose no more than 18 inches adjacent to all foundation structures, including foundation walls, interior piers, pipes, and any other structures with soil contact. After the Termidor H•P II finished dilution has been absorbed by the soil, replace the sealing fabric.
- Location
- Both
- Dilution
- Termidor H•P II finished dilution
Timing & weather
- Before treatment, turn off any air circulation system that moves air from area(s) to be treated to an untreated interior space of the structure until application has been completed and all Termidor H•P II finished dilution has been absorbed by the soil.
Use restrictions 5
- DO NOT drill through hollow block foundations that border the French drain.
- DO NOT broadcast or power spray with high pressure.
- DO NOT contaminate wells or cisterns.
- DO NOT apply Termidor H•P II finished dilution within 10 feet of any well or cistern when using SA-Mode, or within 5 feet of any well or cistern when using HT-Mode.
- When applying Termidor H•P II finished dilution in SA-Mode, soil between 10 and 15 feet from a well or cistern must only be treated by the Backfill Method described below.